VOCÊ TEM UMA PERGUNTA?

CONTATE-NOS

TEM OUTRA PERGUNTA?

Envie-nos um e-mail e faremos o possível para ajudá-lo no que for possível.

Envia-nos um email

PERGUNTAS FREQUENTES

Selecione um produto para obter melhores resultados.

Why does the unit power off when listening to my Phono input?

Several Rotel models feature an Auto Power Down Timer option that will allow the unit to power off automatically after a specified period of time with no signal or activity.

In certain Stereo models, the sleep timer circuitry cannot detect analog signals and so it reacts as if the unit is not in use and shuts down after the timer expires.

The default power off setting is 20 minutes of inactivity for products sold in the UK and EU markets - this setting is based on a recent EU requirement to reduce power consumption. All other regions default the power off timer to Disabled.

In either case above, the timer setting can be easily set or disabled via the Setup menu for the unit. We recommend disabling this feature if you intend to use the device with analog sources such as Turntable or a Tuner.

Modelos aplicáveis:
A12 | A14 | RA-1572 | RA-1592 | RC-1572 | RC-1590

Why doesn’t the RR-969 remote change sources on my Rotel model?

The top two rows of buttons on the RR-969 remote are not used to change sources on the Rotel device, they are used to select the various devices in your system that your RR-969 has been programmed to control.

To switch sources, first make sure you have selected the AUD device button on the top row of the RR-969. Then slide the drawer open on the remote, and the first two rows of buttons below the drawer will allow you to switch between the different inputs on the Rotel device.

Modelos aplicáveis:
RA-1070 | RC-1090 | RSP-1066 | RSX-1065

Why doesn’t the source name on the right side of the front display change when the input is changed?

The source on the right hand side of the front display is the Record source. These models allow the simultaneous recording of one source while listening to another source, using any of the record outputs available (Tape Out, Video 1-3 Out). The record source can be changed by either pressing the REC button on the front panel followed by the desired source, or the ZONE or REC button on the supplied remote.

Modelos aplicáveis:
RA-1070 | RC-1090 | RSP-1066 | RSX-1055 | RX-1050

Why is there both an input and an output 12 volt trigger connection?

This is provided for convenience should the system have more components that use a 12 volt trigger connection than available 12 volt trigger outputs from the preamplifier.  The 12 volt trigger output on the amplifier allows the 12 volt trigger signal to be daisy-chained from the amplifier to another component.

Modelos aplicáveis:
RB-1080 | RB-1090 | RB-1091 | RB-1092 | RB-1510 | RB-1552 | RB-1552 MkII | RB-1562 | RB-1572 | RB-1582 | RB-1582 MkII | RKB-250 | RKB-2100 | RKB-650 | RKB-850 | RKB-8100 | RKB-D850 | RKB-D8100 | RMB-1048 | RMB-1066 | RMB-1075 | RMB-1076 | RMB-1077 | RMB-1085 | RMB-1095 | RMB-1506 | RMB-1512 | RMB-1565 | RMB-1555 | RMB-1575 | RMB-1585

Why won't my RDV-1092 or RDV-1093 DVD player upscale component video to 1080p?

Component video can support a maximum resolution of 1080i. An HDMI connection is required to display a 1080p video signal. Additionally, many DVD movies are copy-protected which limits the maximum allowable analog video resolution to 480p for copy-protected discs unless an HDMI connection is used.

Modelos aplicáveis:
RDV-1092 | RDV-1093

Why won’t my Rotel turn on from Standby via IP control?

Recent EU and UK power regulations mandate that while in Standby mode a product can draw no more than 3W of power, and will further lower the maximum allowed draw to 2W in 2019.

As a result of these new regulations, it is regrettably no longer possible to retain power to the network circuitry while in standby mode as this would draw above the maximum allowed power. The Network Wakeup option has been removed from the setup menu for units sold in the UK and EU markets. This means IP control can no longer be used to power-on a Rotel device from Standby mode.

As an alternative, Rotel models offer 2-way RS232 control as well. All commands available over IP will also work with RS232 and many of the same control systems that work over IP also offer RS232 connection options. For more information or questions regarding control system integration we recommend discussing this with your authorized Rotel dealer.

For situations where IP control is a requirement or a wired RS232 connection is not practical, Ethernet IP to RS232 adapters are commonly available and can be used to provide an IP interface to Rotel models.

Modelos aplicáveis:
A14 | RA-1572 | RA-1592 | RAP-1580 | RC-1572 | RC-1590 | RSP-1576 | RSP-1582

Will my CD player read CDR or CDRW discs?

All Rotel CD players from the 10 series and newer can read CDR discs. We cannot guarantee 100% compatibility however, due to the large differences in media and CD writers available.

Most Rotel CD players cannot read CDRW discs. Only the RCD-1520, RCD-1570, RCX-1500 and RCD-12 models can read both CDR and CDRW discs.

Modelos aplicáveis:
CD11 | CD14 | RCC-1055 | RCD-06 | RCD-12 | RCD-1070 | RCD-1072 | RCD-1520 | RCD-1570 | RCX-1500

Will my DVD player play HD-DVD or Blu-Ray discs?

No. Blu-Ray and HD-DVD are different formats that require a different type of laser to read and therefore require special players. Your Rotel player is a standard DVD player and therefore will not support these high resolution discs.

Modelos aplicáveis:
RDV-1040 | RDV-1045 | RDV-1050 | RDV-1060 | RDV-1080 | RDV-1092 | RDV-1093

Will my Rotel DVD player read CDR or CDRW discs?

The following DVD player models can read both CDR and CDRW discs, as well as MP3 and JPEG files stored on these discs:

  • RDV-1040
  • RDV-1045
  • RDV-1050
  • RDV-1060
  • RDV-1092
  • RDV-1093

The RDV-1080 does not have a dual laser mechanism that is required for CDR playback. However, it may read some CDRW discs, though 100% compatibility is not guaranteed due to the many different types of media and CD writers available.

Modelos aplicáveis: